Ubuy tekee kovasti töitä turvallisuutesi ja yksityisyytesi suojaamiseksi. Kehittynyt maksun turvallisuusjärjestelmämme varmistaa luottamuksellisuuden salaamalla tietosi siirron aikana AES (Advanced Encryption Standards)- ja SSL (Secure Socket Layer) -protokollilla. Maksutietosi ovat 100 % turvassa, sillä emme jaa maksutietojasi kolmansien osapuolten myyjille.
The BK1120 EtherCAT Coupler seamlessly connects your EtherCAT protocol with up to 64 Bus Terminals for optimal performance.
Osta nyt, maksa myöhemmin
Fast
Shipping
Ilmainen
palautus*
Pakattu turvallisesti
100-prosenttisesti alkuperäistuotteita
PCI DSS Compliance
ISO 27001 Certified
Mikä erottuu joukosta
Tuotteen yksityiskohdat
- The BK1120 EtherCAT Coupler is the link between the EtherCAT protocol at fieldbus level and the Bus Terminals.The coupler converts the passing telegrams from Ethernet 100BASE-TX to the internal, fieldbus-independent terminal bus.
- A station consists of a coupler and up to 64 Bus Terminals plus a bus end terminal.
- The process image of the EtherCAT system is assigned automatically.Up to 255 Bus Terminals can be connected via the K-Bus extension.
- Special features:
- Connection technology: 2 x RJ45 socket ;Connection lengths: up to 100 m
- connects the EtherCAT protocol with the Bus Terminals;The BK1120 has two RJ45 sockets. The upper Ethernet interface is used to connect the coupler to the network; the lower socket serves for the optional connection of further EtherCAT devices in the same segment.
- The system and field supply, each 24 V DC, is provided directly at the coupler. The attached Bus Terminals are supplied with the current required for communication from the supplied system voltage.
- The field supply is forwarded to the individual I/O components via the power contacts with up to 10 A.
- In the EtherCAT network, the BK1120 coupler can be installed anywhere in the Ethernet signal transfer section (100BASE-TX) – except directly at the switch.
- The EK9000 and EK1000 couplers are suitable for use at the switch.
| Tuotteen paino | 1 lbs (450 grammaa) |
Product Technical Details
| Valmistaja | Vanky Industry |
| Kohteen mallinumero | BK1120 |
Mitä pakkauksessa on
Ei
Kenelle sopii?
-
Industrial Automation
Ideal for users in industrial settings looking to integrate various I/O modules with EtherCAT systems seamlessly.
-
Control System Integrators
Beneficial for integrators requiring reliable communication between different automation components in complex systems.
-
Modular Applications
Perfect for developers needing a flexible bus coupler to adapt to changing project requirements or hardware configurations.
-
Small-Scale Projects
Not suitable for users with smaller automation needs that do not require the extensive features of this module.
-
Budjetti-tietoiset käyttäjät
May not be ideal for individuals or companies with tight budgets due to its higher price point in comparison.
-
Basic DIY Applications
The product is too advanced for casual DIY projects, needing more user expertise for setup and configuration.
TUOTEKUVAUS.
Asiakkaiden kysymykset ja vastaukset
-
kysymys:
What is the purpose of the BECKHOFF BK1120 Module Bus Coupler?
vastaus: The BECKHOFF BK1120 Module Bus Coupler is designed to connect various I/O modules to a higher-level bus system. It acts as an interface, translating commands and enabling communication between the PLC and different field devices. This functionality is crucial in a modular automation setup, allowing you to integrate multiple I/O solutions seamlessly. -
kysymys:
What types of I/O modules can be connected to the BK1120?
vastaus: The BK1120 is compatible with a broad range of BECKHOFF I/O modules, including digital and analog types. This flexibility allows users to customize their automation solutions based on specific project needs, making it suitable for various applications from simple control tasks to complex industrial automation processes. -
kysymys:
How is the BK1120 Module configured?
vastaus: Configuration of the BK1120 is typically done through PC-based software tools, such as TwinCAT. These tools provide user-friendly interfaces for setting up network parameters, configuring I/O modules, and managing communication processes. By utilizing these software solutions, users can easily tailor the module to their operational needs. -
kysymys:
Is the BECKHOFF BK1120 suitable for industrial applications?
vastaus: Yes, the BECKHOFF BK1120 is specifically designed for use in industrial environments. Its robust construction and compatibility with various industrial protocols (like EtherCAT) make it ideal for demanding tasks in automation, ensuring reliability and performance in applications ranging from manufacturing to process control. -
kysymys:
What communication protocols does the BK1120 support?
vastaus: The BK1120 supports several communication protocols, including EtherCAT and other fieldbus systems. This capability allows it to connect effectively with different control systems, communication networks, and field devices, ensuring seamless integration and data exchange in complex systems. -
kysymys:
Can the BK1120 be used in a mixed vendor environment?
vastaus: Yes, one of the advantages of the BECKHOFF BK1120 is its ability to function in a mixed vendor environment. Thanks to its support for various communication protocols, it can interoperate with devices and systems from different manufacturers, providing greater flexibility in automation design and implementation. -
kysymys:
What are the main features of the BK1120 Module?
vastaus: Key features of the BECKHOFF BK1120 include its modular design, support for a wide range of I/O modules, robust industrial-grade build, and compatibility with numerous communication protocols. Additionally, its ability to provide real-time data acquisition and processing makes it an essential component in automation applications that require precise control and monitoring. -
kysymys:
What power requirements are needed for the BK1120?
vastaus: The BECKHOFF BK1120 typically operates at a standard voltage and power requirement that matches most industrial environments. It is essential to consult the product documentation for specific details regarding power input to ensure proper functionality within your system and avoid potential issues. -
kysymys:
Does the BK1120 support remote monitoring?
vastaus: Yes, the BECKHOFF BK1120 supports remote monitoring functionalities, allowing users to oversee system performance and operational data over a network. This feature is particularly useful in large-scale industrial applications where maintaining oversight and control remotely can enhance response times and efficiency. -
kysymys:
Where can I buy the BECKHOFF BK1120 Module Bus Coupler New?
vastaus: You can buy the BECKHOFF BK1120 Module Bus Coupler New on Ubuy in Finland. Ubuy is a reliable online shopping platform that stocks a variety of electronic and automation products, ensuring you can find the equipment you need for your projects with ease.
Vanky Industry Industrial Electrical Editorial Review
Asiakkaiden arvostelut ja arvosanat
-
5 tähteä
100%
-
4 tähteä
0%
-
3 tähteä
0%
-
2 tähteä
0%
-
1 tähteä
0%
Arvostele tämä tuote
Jaa ajatuksesi muille asiakkaille
Tuotteen hintahistoria
Tärkeitä tietoja
- Rajoitukset: Kansainvälisesti toimitettujen tuotteiden kohdalla tulee ottaa huomioon, ettei valmistajan takuu välttämättä ole voimassa, etteivät valmistajan huoltovaihtoehdot välttämättä ole käytettävissä, etteivät tuotteen ohjekirjat, oppaat ja turvallisuusvaroitukset välttämättä ole kohdemaan kielellä, ettei tuotteita (ja niiden oheismateriaalia) ole välttämättä suunniteltu vastaamaan kohdemaan standardeja, teknisiä tietoja ja merkintävaatimuksia ja etteivät tuotteet välttämättä vastaa kohdemaan jännitettä ja muita sähköstandardeja (jolloin ne saattavat tarvittaessa vaatia sovittimen tai muuntimen käyttöä). Vastaanottaja on vastuussa sen varmistamisesta, että tuote voidaan toimittaa kohdemaahan laillisesti. Kun vastaanottaja tekee tilauksen Ubuysta tai sen kumppanuusyhtiöiltä, hän on myös rekisteröity maahantuoja ja hänen tulee noudattaa kaikkia kohdemaan lakeja ja säädöksiä.
- Kaikki Ubuyssa listatut tuotteet eivät ole myytävänä, koska Ubuy on maailmanlaajuinen hakukone. Tuotteisiin kohdistuu vienti- ja myyntisäännöksiä.
€ 210
Tee tilaus nyt, niin saat tuotteen noin Tiistai, Heinäkuu 28
This item is not restrict in my country.(Please click on above link if this item is not restrict in your country, So our team will review and allow.)
QTY:
Ubuy tekee kovasti töitä turvallisuutesi ja yksityisyytesi suojaamiseksi. Kehittynyt maksun turvallisuusjärjestelmämme varmistaa luottamuksellisuuden salaamalla tietosi siirron aikana AES (Advanced Encryption Standards)- ja SSL (Secure Socket Layer) -protokollilla. Maksutietosi ovat 100 % turvassa, sillä emme jaa maksutietojasi kolmansien osapuolten myyjille.
Ominaisuudet ja hyödyt
- Connects EtherCAT protocol to Bus Terminals efficiently.
- Supports up to 64 Bus Terminals in a single station.
- Automatic assignment of EtherCAT system process images.
- Robust connection technology with dual RJ45 sockets.
- Field supply offers up to 10 A for reliable communication.
- Flexible installation in the Ethernet signal transfer section.